Neutron-physical parameters at the outlet of the WWR-K reactor beam tube
Abstract
The paper is devoted to the neutron-physical parameters obtained via combined calculations and experimental measurements for the exit of the WWR-K reactor beam tube. The experimentally measured values of the thermal and fast neutron flux densities at the exit comprise 9.6 × 108 and 8.4 × 107 cm-2 s-1 , respectively. The dose rate of gamma-emission is 30 Sv/h. The obtained parameters will be used in designing of the collimation and screening systems of the installation for radiography and tomography to be created at the beam tube #1.
Recommended Citation
Bauyrzhan, A. B.; Koltochnik, S. N.; Aitkulov, M. T.; Dyussambayev, D. S.; Shaimerdenov, A. A.; Mukhametuly, B.; and Burtebaev, N. T. (2019) "Neutron-physical parameters at the outlet of the WWR-K reactor beam tube," Eurasian Journal of Physics and Functional Materials: Vol. 3: No. 3, Article 3.
DOI: https://doi.org/10.29317/ejpfm.2019030303
References
Downloads
Published
Issue
Section
License
The Eurasian Journal of Physics and Functional Materials is an open-access journal. Articles published under the Creative Commons Attribution 4.0 International License (CC BY 4.0) may be shared, redistributed, and adapted, including for commercial purposes, provided that the terms of the license are followed, including appropriate attribution to the original authors and source.