Detector-Level Transport Regimes in Polyethylene/Aluminium Shielding of Silicon Sensors under Photon, Electron, and Proton Irradiation
DOI:
https://doi.org/10.32523/ejpfm.2026100405Keywords:
Geant4, silicon detector, polyethylene, aluminium, radiation shielding, secondary particles, proton range-outAbstract
Shielding performance inferred from attenuation or nominal thickness can misrepresent the response of a finite semiconductor detector. This study uses Geant4 to map energy deposited in a silicon sensor of dimensions 20 mm × 20 mm × 0.5 mm behind polyethylene (PE) and PE–aluminium (PE–Al) shields under controlled photon, electron, and proton fields. Event-level scoring separates primary survival, residual entry energy, shield-generated secondaries, and finite shield coverage. The proton response was strongly non-monotonic near range-out: effective suppression occurred between 8–9 mm PE at 30 MeV and between 20–25 mm PE at 50 MeV, in agreement with NIST PSTAR projected ranges. For photons, short shield-to-sensor gaps increased silicon energy deposition, consistent with enhanced acceptance of shield-generated secondaries. At the final 100 mm gap, adding 0.5 mm Al to 25 mm PE improved the photon-response reduction by 3.083 ± 0.558 percentage points under the reference physics list; the uncertainty is a two-sided 95% sampling confidence-interval half-width and excludes physics-model uncertainty. An XCOM narrow-beam calculation gave 1.01 percentage points of additional uncollided primary-photon number removal, a different observable that cannot be subtracted from the detector-response change to quantify a secondary contribution. A finite-size test further showed that oblique protons could traverse an edge-clipped path in a nominally thick shield. Within the discrete candidate set, 25 mm PE was the lowest-mass configuration with positive mean response reduction in all four benchmark fields. These results define transport and geometry regimes that should be checked before a shielding design is advanced to mission-specific modelling or experimental qualification.
References
[1] J.R. Srour, J.M. McGarrity, Proceedings of the IEEE 76 (1988) 1443–1469.
[2] G.C. Messenger, M.S. Ash, The Effects of Radiation on Electronic Systems, 2nd ed. (Van Nostrand Reinhold, New York, 1992) 951 p.
[3] R.H. Maurer, M.E. Fraeman, M.N. Martin, D.R. Roth, Johns Hopkins APL Technical Digest 28 (2008) 17–29.
[4] S. Bourdarie, M. Xapsos, IEEE Transactions on Nuclear Science 55 (2008) 1810–1832.
[5] H. Daneshvar et al., Scientific Reports 11 (2021) 20657.
[6] A. Gohel, R. Makwana, Radiation Physics and Chemistry 197 (2022) 110131.
[7] A. Fetzer, M. Anger, P. Oleynik, J. Praks, Advances in Space Research 73 (2024) 831–845.
[8] J. Su et al., Advances in Space Research 73 (2024) 2652–2662.
[9] F. Cordella et al., The European Physical Journal Plus 139 (2024) 150.
[10] M.J. Berger et al., ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions, Version 1.2.3, National Institute of Standards and Technology, Gaithersburg, MD, 2005.
[11] M.J. Berger et al., PSTAR: Stopping-Power and Range Tables for Protons, National Institute of Standards and Technology, Gaithersburg, MD, 2005.
[12] International Commission on Radiation Units and Measurements, Stopping Powers and Ranges for Protons and Alpha Particles, ICRU Report 49, Bethesda, MD, 1993.
[13] M.J. Berger et al., ESTAR: Stopping-Power and Range Tables for Electrons, National Institute of Standards and Technology, Gaithersburg, MD, 2005.
[14] International Commission on Radiation Units and Measurements, Stopping Powers for Electrons and Positrons, ICRU Report 37, Bethesda, MD, 1984.
[15] M.J. Berger et al., XCOM: Photon Cross Section Database, Version 1.5, National Institute of Standards and Technology, Gaithersburg, MD, 2010.
[16] S. Agostinelli et al., Nuclear Instruments and Methods in Physics Research Section A 506 (2003) 250–303.
[17] J. Allison et al., IEEE Transactions on Nuclear Science 53 (2006) 270–278.
[18] J. Allison et al., Nuclear Instruments and Methods in Physics Research Section A 835 (2016) 186–225.
[19] R. Brun, F. Rademakers, Nuclear Instruments and Methods in Physics Research Section A 389 (1997) 81–86.
[20] Geant4 Collaboration, Guide for Physics Lists, Geant4 Version 11.2, Geant4 Documentation, 2023.
[21] Geant4 Collaboration, Shielding Reference Physics List, Geant4 Version 11.2, Geant4 Physics List Guide, 2023.
[22] NIST/SEMATECH, e-Handbook of Statistical Methods, Section 7.2.4.1: Confidence Intervals for a Binomial Proportion, National Institute of Standards and Technology.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Y. Havvat (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.
The Eurasian Journal of Physics and Functional Materials is an open-access journal. Articles published under the Creative Commons Attribution 4.0 International License (CC BY 4.0) may be shared, redistributed, and adapted, including for commercial purposes, provided that the terms of the license are followed, including appropriate attribution to the original authors and source.
License: https://creativecommons.org/licenses/by/4.0/
Copyright ownership and publication rights are governed by the terms applicable to each article and the relevant author agreement.